Pagina 1 - Conformal Curing Oven

Conformal Curing Oven TC V3 Maintenance Manual P/N 7211568

Pagina 2

2-2 Safety Basic Safety Precautions and Practices The following precautions and practices are recommended during Cure Module operation and maintenanc

Pagina 3 - Trademarks

Safety 2-3 Earthquake Precautions In the event of an earthquake, the cure module must be secured to prevent movement that could cause injury to perso

Pagina 4

2-4 Safety 4. Reset the main circuit breaker inside the electronics enclosure if it has been tripped. 5. Turn the red EMO button clockwise until it

Pagina 5 - Table of Contents

Safety 2-5 Lockout of Electrical Energy TC V3 Cure Module electrical components have been designed in accordance with industry-wide safety standards.

Pagina 7 - 1 Introduction

Maintenance 3-1 3 Maintenance Overview Performing the recommended maintenance and service procedures increases the life of your Cure module and ens

Pagina 8

3-2 Maintenance Preventive Maintenance Table 3-1 Preventive Maintenance Recommended Frequency Maintenance Procedure Instructions WEEKLY – 120 h o

Pagina 9 - 2 Safety

Maintenance 3-3 Maintenance Procedures CAUTION!Safety Maintenance procedures should only be performed by trained service technicians. Refer to the

Pagina 10 - Safety of Personnel

3-4 Maintenance Conveyor Incremental Encoder Adjustment The Conveyor Incremental Encoder returns an accurate measurement of conveyor speed to the PLC

Pagina 11 - Emergency Shutdown

Maintenance 3-5 Conveyor Chain Tension Adjustment To adjust the tension of the conveyor chains: 1. Turn the power off by moving the Main Switch to t

Pagina 13 - Lockout of Electrical Energy

3-6 Maintenance Transmission Chain Tension Adjustment To adjust the tension of the transmission chain: 1. Turn the power off by moving the Main Swit

Pagina 14

Maintenance 3-7 Adjustment of the Rail Parallelism If a printed circuit board (PCB) falls down into the oven, the conveyor rail needs adjustment. To

Pagina 15 - 3 Maintenance

3-8 Maintenance 5. If the input and output measurements are not equal, remove the access cover located under the crank to access the transmission ge

Pagina 16 - Preventive Maintenance

Maintenance 3-9 Figure 3-10 Output Rail 8. If the three measurements are not equal, remove the screws from the rail fixation and adjust the posit

Pagina 17 - Maintenance Procedures

3-10 Maintenance Thermocouple Replacement To replace a thermocouple: 1. Turn the power off by moving the Main Switch to the OFF position. 2. Open

Pagina 18 - CAUTION!

Maintenance 3-11 Resistor Replacement To replace the top resistor: CAUTION!1. Turn the power off by moving the Main Switch to the OFF position. B

Pagina 19 - Maintenance 3-5

3-12 Maintenance 6. Unscrew the retaining nut on the cable. Figure 3-15 Stuffing Box Figure 3-16 Joint 7. Unscrew the nut on the stuffing box

Pagina 20 - 3-6 Maintenance

Maintenance 3-13 13. Replace the top access cover. 14. Close the hood using proper procedures described in “Hood Opening/Closing Operation” of the

Pagina 21

3-14 Maintenance 11. Re-attach the clips on the maintenance part. 12. Check to make sure the new resistor is positioned in line with the glass. 13.

Pagina 22 - 3-8 Maintenance

Maintenance 3-15 Adjustment of the Dropped Board Detection Cell (optional) To adjust the dropped board detection cell: 1. Turn the power on by movin

Pagina 23 - Maintenance 3-9

P/N 7211568, Revision C English Translation based on French P/N 7211572, Rev. B ©2010 NOTICE This is a Nordson ASYMTEK publication, which is protect

Pagina 24 - Thermocouple Replacement

3-16 Maintenance Auto-Tune Procedure The purpose of the auto-tune is to set PID parameters of temperature control loops. This function is used only i

Pagina 25 - Resistor Replacement

Maintenance 3-17 3. Click on a graphical visualization of a zone (Figure 3-29). Figure 3-29 Graphic Visualization of a Zone 4. Apply the values

Pagina 27 - Maintenance 3-13

Troubleshooting 4-1 4 Troubleshooting Overview Troubleshooting helps you identify common problems that you may experience with your cure module and

Pagina 28 - 3-14 Maintenance

4-2 Troubleshooting Alarms / Trouble Possible Causes Verifications and Actions Alarm Conveyor 2 – Speed Band Alarm Speed Sensor defective Check th

Pagina 29 - Maintenance 3-15

Troubleshooting 4-3 Alarms / Trouble Possible Causes Verifications and Actions Board Jam Alarm Photo cell defective Adjust the sensor (refer to the

Pagina 31 - ZR : 0 °C ZR : 0°C

Parts List 5-1 5 Parts List This section contains parts ordering information for the TC V3 Conformal Curing Oven. Part number information is also a

Pagina 32

5-2 Parts List Level 3 - Long Lead-Time Parts Figure 5-3 Parts with a long procurement lead-time or for software update. Designation Reference Ma

Pagina 35 - Troubleshooting 4-3

P/N 7211568 Revision C ©2010 Nordson ASYMTEK Headquarters 2762 Loker Avenue West Carlsbad, CA 92010-6603 USA Tel: (760)

Pagina 36

Table of Contents i Table of Contents 1 Introduction ...

Pagina 37 - 5 Parts List

ii Table of Contents Table of Figures Figure 3-1 Torque Limiter Adjustment ...

Pagina 38 - 5-2 Parts List

Introduction 1-1 1 Introduction Overview This manual covers maintenance procedures necessary for the preventive and corrective maintenance of the T

Pagina 40

Safety 2-1 2 Safety Overview Operation of the TC V3 Conformal Curing Oven involves heat, electrical power, mechanical devices, and the use of hazar

Comentarios a estos manuales

Sin comentarios