Maintenance 3-17
3. Click on a graphical visualization of a zone (Figure 3-29).
Figure 3-29 Graphic Visualization of a Zone
4. Apply the values below according to the type of regulator (PI or PID) you want (Table 3-3).
Table 3-3 Regulator
Regulator PI Regulator PID
Gain : 1 Gain : 1
TI : 0 s TI : 0 s
TD : 0 s TD : 9999 s
ZR : 0 °C ZR : 0°C
5. Enter the temperature set point (150 °C max).
6. Wait for stability of the oven.
7. Click on Auto Tune.
8. Click on Start.
9. Wait for the end of "AUTO TUNE" and repeat for the remaining zones.
CAUTION! DO NOT STOP the oven during "AUTO TUNE".