Troubleshooting 4-3
Alarms / Trouble Possible Causes Verifications and Actions
Board Jam Alarm
Photo cell defective
Adjust the sensor (refer to the Conveyor Counter Cell
Adjustment procedure)
Check the wiring.
Improper alignment of the oven
with the downstream machine
Check and adjust the position of the downstream
machine if necessary.
Input Transfer Alarm
Photo cell defective
Adjust the sensor (refer to the Conveyor Counter Cell
Adjustment procedure)
Check the wiring.
Improper alignment of the oven
with the downstream machine
Check and adjust the position of the downstream
machine if necessary.
Downstream Alarm Downstream machine down Check the downstream machine status.
Lubricator Alarm Level Lower oil level Fill oil tank.
Humidifier Alarm Humidifier error Check the humidifier status.